When it comes to ensuring security in business, industrial, and property spaces, slip resistance testing is a vital factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist businesses and homeowner mitigate threats and comply with safety standards.

With modern devices such as the pendulum slip test maker and moisture meter for concrete, we provide accurate and independent slip testing services throughout Australia. Our expertise covers ASTM F2170 compliance, R Rating assessments, P Rating tiles, and more, guaranteeing your floorings fulfill the greatest safety criteria.

Why Slip Resistance Testing is Important


Slips and falls are among the leading causes of workplace and public injuries. Correct slip testing assists recognize dangerous surfaces before mishaps take place. Whether you require wet pendulum test evaluations or pendulum test for slip resistance, ATTAR delivers exact outcomes to improve safety.

Key Services Used by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Ranking and P Score tiles assessments.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test using advanced moisture meter for concrete.
- ASTM F2170 certified evaluations.
- Concrete slab moisture testing to prevent flooring failures.

3. Luminance Contrast Testing

- Ensures exposure for visually impaired people.
- Complies with Australian availability standards.

4. On-Site & Laboratory Testing

- Slip test maker for precise on-site evaluations.
- Wet pendulum test for damp surface area slip resistance.

Understanding Slip Resistance Ratings: R Ranking vs. P Score


When conducting slip resistance testing, 2 essential classifications are utilized:.

- R Score (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, frequently used in Europe.

- P Rating (Pendulum Test - AS 4586)
Examines dynamic friction utilizing a pendulum test slip resistance device, widely embraced in Australia.

ATTAR offers independent slip testing to figure out whether your floor covering meets the needed pendulum rating tiles requirements.

The Significance of Concrete Moisture Testing


Excess moisture in concrete slabs can lead to floor covering failures, mold growth, and adhesive destruction. Our concrete moisture testing services include:.

> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to make sure ideal conditions for floor setups.

By discovering moisture issues early, we assist prevent expensive repair work and guarantee lasting flooring efficiency.

Luminance Contrast for Ease Of Access Compliance


Correct luminance contrast is essential for aesthetically impaired individuals to browse areas safely. ATTAR assesses:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.

Our evaluations make sure compliance with Australian Impairment Standards (AS 1428.1).

Why Pick ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where appropriate).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Coverage.
> Fast & Trusted Reporting.

For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Typical Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping centres, restaurants, and workplaces need safe flooring to prevent client and staff member injuries. Our pendulum slip test ensures compliance with security guidelines.

2. Industrial & Warehouse Facilities

High-traffic industrial environments require durable, slip-resistant flooring. ATTAR's slip testing services help keep workplace safety.

3. Healthcare & Aged Care Facilities

Health centers and nursing homes should decrease slip threats. Our luminance contrast and slip resistance testing ensure safe mobility for clients and personnel.

4. Public Infrastructure

Walkways, train stations, and federal government structures need independent slip testing to meet accessibility and safety requirements.

How ATTAR Performs Slip Resistance Testing


Action 1: Surface Area Evaluation

We evaluate flooring materials and conditions (dry, wet, or polluted).

Action 2: Pendulum Slip Test (AS 4663)

Utilizing a slip test maker, we determine the vibrant coefficient of friction (DCOF).

Step 3: Wet Pendulum Test

Simulates slippery conditions to assess real-world slip dangers.

Step 4: Reporting & Compliance Certification

Comprehensive reports with R Score or P Ranking tiles categories.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance approach includes a swinging arm with a rubber slider that simulates a foot's motion. The test procedures:.

- Slip Possible Worth (SPV).
- Pendulum ranking tiles category (P0 to P5).

Greater rankings (P4/P5) show much better slip resistance.

Moisture Testing for Concrete Floors: Avoiding Failures


Moisture-related floor covering failures can be pricey. ATTAR's concrete slab moisture testing consists of:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete get more info check.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast assessments. With advanced technology like the pendulum slip test and moisture meter for concrete, we deliver accurate, independent, and compliant testing services.

Guarantee your home fulfills security requirements-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By selecting ATTAR, you purchase independent slip testing services, pendulum test slip resistance accuracy, and long-term floor security options. Let us assist you produce safer, compliant, and moisture-resistant environments.

Report this page